With the Puls-air workshop heating 50 % save heating costs

50 % of heating cost savings

Contact us

Werner Pletzer Autohaus-Puls Air GmbH
Innsbruckerstrasse 10
A-6353 Going

Contact: +43 5358 3600, info@pulsair.net

Contact AUT: +43 664 20 15 883, austria@pulsair.net

Please enable JavaScript in your browser to complete this form.
Name
Selected value: 3

Pletzer Luca, Georg & Werner will be happy to advise you

FAQ

Basically you can say:

Puls-air standard with very good insulation 600 m³.

Puls-air Plus up to max. 1800 m³ with good insulation, 1000-1200 m³ with poor insulation

Halls or workshops that were built up to 5 years ago are very well insulated. This means insulating glazing, gas concrete walls or sandwich panels 100 mm or 120 mm.

Poorly insulated halls, for example, are just brick buildings with a bad roof.

Room temperature as desired. Based on empirical values, the room temperature in the workshop can be lowered by approx. 4 degrees while maintaining the same level of comfort for employees, because the heat comes from below. This is in contrast to ceiling fans from above, which wastes energy pointlessly.

Yes, because a room thermostat is installed on the appliance, which automatically switches the appliance off and on to maintain the set temperature.

The external heating oil tank must be obtained from the local heating engineer. Requirements: Double-walled, leak indicator & fire protection valve. 

No, the appliance can be connected to an external heating oil tank via an 8 mm copper pipe. Attention: No return flow - single-pipe system. The tank can be up to 30 m away and the height difference must not exceed 3.5 m.

The advantage of the canister is that the appliance is immediately ready for use.

Approx. 57 dBa, measured in a reference room. The actual noise sensation in a normally equipped workshop or hall is a pleasant slight hum.

It is often difficult to judge volume.
  • 30 dB: Whispering, own breathing noise.
  • 35 dB: rustling of leaves.
  • 40 dB: In the living room with the window closed.
  • 45 dB: Residential areas without road traffic.
  • 60 dB: Conversation (single conversation)
  • 70 dB: Open plan office.
  • 85 dB: Average road traffic.
  • 95 dB: Heavy goods traffic.

(Source Google)

Puls-air standard: 1.5 l/h on the economy setting and 1.9 l/h on the full power setting

Puls-air Plus: 1.9 l/h on the economy setting and 2.5 l/h on the full power setting

Attention: Do not calculate for the whole day, as the appliance always switches itself on and off by the thermostat to maintain the temperature.

We always ask the counter question: How much do you currently need? - From this minus 50 % and then you have the total (all in approximate figures)

Yes, but we have to connect it according to the wiring diagram because the fan has to run on.

App control is possible. Your local electrician should contact us about this!

There are basically 2 models: Puls-air Standard (up to 600m³) and Puls-air Plus (with good insulation up to 1,800m³). For even larger rooms, 2 or more devices can be operated together. This means that even larger halls and workshops can be heated efficiently and economically. 

All prices on this website are excl.. VAT. to be understood. The delivery costs are listed separately in the checkout process.

180 W or 0.18 KW i.e. 0.18 KWh power consumption per hour

The operation of heaters with waste oil below 50 kW is prohibited. Diesel or heating oil is used as fuel for Puls-air.

32 x 1.5mm wall thickness = 35mm outer diameter

The flue pipes are not included in the scope of delivery and must be ordered separately. About this Link to get to the product range.

We will be happy to inform you about current delivery times by email, WhatsApp or telephone.

  1. Disconnect the supply and return lines (attached to the right of the oil filter) at the oil filter and hang them in a container with heating oil.
  2. Switch on the device and wait until it starts.
  3. Once the device has started, reattach the two cables.
  4. Loosen the supply line (attached to the left of the oil filter) at the oil filter and also switch on the appliance.
  5. Reattach the inlet pipe, the problem should be solved.

Exhaust gas values (NOX - 25 - 30, CO - 2 - 5 ppm; soot number 00)

No, please do not use a diesel-petrol mixture either!