Basically you can say:

Puls-air standard with very good insulation 600 m³.

Puls-air Plus up to max 1800 m³ with good insulation, with poor insulation 1000-1200 m³.

Very well insulated are halls or workshops built up to 5 years ago. This means insulating glazing, gas concrete walls or sandwich panels 100 mm or 120 mm.

Poorly insulated halls, for example, are just masonry buildings with poor roof.

Room temperature as desired. Based on empirical values, the room temperature of the workshop can be reduced by approx. 4 degrees, while maintaining the same comfort level for the employees, because the heat comes from below. Compared to ceiling fans from above, therefore energy is senselessly wasted.

Yes, because a room thermostat is built into the unit, which automatically turns the unit off and on to maintain the set temperature.

The external fuel oil tank is to be obtained from the local heating contractor. Requirements: Double walled, leak detection & fire protection valve.

No, the unit can be connected to an external fuel oil tank via 8mm copper pipe. Attention: No return - single line system. The tank can be up to 30 m away and the height difference must be max. 3.5 m.

The advantage of the canister is that the device is immediately ready for use.

Approx. 57 dBa, measured in a reference room. The actual noise sensation in a normally equipped workshop or hall is a pleasant light hum.

Judging loudness is often difficult.
  • 30 dB: Whispering, own breathing sound.
  • 35 dB: Leaf rustling.
  • 40 dB: In the living room with the window closed.
  • 45 dB: Residential area without road traffic.
  • 60 dB: Entertainment (single conversation)
  • 70 dB: Open plan office.
  • 85 dB: Average road traffic.
  • 95 dB: Heavy traffic.

(Source Google)

Puls-air Standard: 1.5 l/h at the economy level and 1.9 l/h at the full power level

Puls-air Plus: 1.9 l/h at the economy level and 2.5 l/h at the full power level

Attention: Do not calculate on the complete day, because the device always switches itself on and off by the thermostat to maintain the temperature.

We always ask the counter question: How much do you need at the moment? - From this minus 50% and then you have the sum (All in approximate figures)

Yes, but this must be connected by us according to the circuit diagram, because the fan must run after.

App control is possible. Your local electrician should contact us in this regard!

Basically there are 2 models: Puls-air Standard (up to 600m³) and Puls-air Plus (with good insulation up to 1,800m³). For even larger premises, 2 or more units can be operated together. Thus, even larger halls and workshops can be heated efficiently and economically. 

All prices on this website are exclusive of VAT. Delivery costs are listed separately in the checkout process.

180 W or 0.18 KW i.e. 0.18 KWh power consumption per hour

Operation of heaters with waste oil under 50 kW is prohibited. Diesel or fuel oil serve as fuel for Puls-air.

32 x 1.5mm wall thickness = 35mm outer diameter

The exhaust pipes are not included and must be ordered separately. Via this link you will get to the assortment.

We will be happy to inform you about the current delivery times by mail, Whatsapp or phone.

  1. Disconnect the supply and return lines (attached to the right of the oil filter) at the oil filter and hang them in a container of fuel oil.
  2. Switch on the device and wait until it starts.
  3. When the device has started, reattach the two wires.
  4. Loosen the supply line (attached to the left of the oil filter) at the oil filter and also switch on the unit.
  5. Reattach the supply line, the problem should be solved.

Exhaust gas values (NOX - 25 - 30, CO - 2 - 5 ppm; soot number 00)