50 % of heating cost savings
For Mr. Hartig it is clear that with the new Puls-air heating system he has far lower heating costs than with the old heating oil burner. The workshop has around 800 cubic meters and is up to temperature in just a few minutes.
Especially in times of high wage and energy
energy costs, it is important to save costs wherever possible. Therefore
Mr. Hartig has therefore decided to replace his ageing oil burner with an innovative
for an innovative Puls-air workshop and hall heating system from Austria.
from Austria.
Puls-air also runs on diesel or heating oil and can therefore be connected to the existing tank. Thanks to the innovative and patented combustion technology, which has been awarded the national prize, with an efficiency of over 97 %, workshop and hall owners can save more than half of their heating costs.
In addition, the physically sensible positioning on the floor, where work is carried out, drastically reduces heating costs. With ceiling fans, the warm air never reaches the zone where it is needed, but collects on the ceiling. Puls-air releases the warm air at the bottom, it is distributed, rises, cools down again at the top and, preheated, is repeatedly drawn in and circulated by the appliance. This effect is known as a "slowly rotating thermal air roll".
Anyone who spends a lot of time in the workshop knows the problem. Constant loud noises or unpleasant odors are bad for your health. Puls-air runs very quietly, some customers report a "whispering concert", and produces no odor whatsoever. In addition, the exhaust values are excellent and pollutants are barely measurable.
The only exhaust system used is a 35 mm stainless steel pipe, which must be led outside. No complex separate chimney, no expensive fitters, just plug and play.
There are 2 models of Puls-air. Puls-air Standard up to 600 m³ and Puls-air Plus up to 1,800 m³. Both values with very good insulation. For larger rooms, several devices can also be used in combination.
With conventional ceiling fans, a lot of heat is lost through long pipes. Heating large quantities of water in the boiler also requires a lot of energy. In addition, conventional oil burners have poor efficiency. With Puls-air, the efficiency is 97 %, which means that almost all the fuel that is introduced is converted into heat. In addition, Puls-air stands on the floor of the room to be heated, releases the warm air where it is being used and creates a slowly rotating thermal air roll in the room. The air is not always heated from 0, but is drawn through the heater again and again, preheated.
GF Schinagl also notices positively that the running noise of Puls-air is much more pleasant and that much less dust is whirled up than with the ceiling fans.
BAVARIAN STATE PRIZE FOR SPECIAL TECHNICAL ACHIEVEMENTS IN THE SKILLED CRAFTS SECTOR
AUSTRIAN STATE PRIZE FOR ENERGY RESEARCH AND THE ENVIRONMENT
Request information material:
Operating instructions, folder, data sheet in German, English and Dutch.
Imprint | AGB & Data protection | Order form as PDF | Online order | Contact us | Operating instructions | Operating instructions
Puls-air heaters | Innsbruckerstraße 10 | A-6353 Going am Wilden Kaiser